OWNER
S OPERATION AND INSTALLATION MANUAL
WARNING: Improper installation,
adjustment, alteration, service or mainte-
nance can cause injury or property damage.
Refer to this manual for correct installation and
operational procedures. For assistance or
additional information consult a qualified
installer, service agency, or gas supplier.
This appliance may be installed in an aftermar-
ket* permanently located, manufactured
(mobile) home, where not prohibited by local
codes.
This appliance is only for use with the type of
gas indicated on the rating plate. This
appliance is not convertible for use with other
gases.
*Aftermarket: Completion of sale, not for purpose of
resale, from the manufacturer.
Do not store, or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
l Do not try to light any appliance.
l Do not touch any electrical switch; do not
use any phone in your building.
l Immediately call your gas supplier from a
neighbors phone. Follow the gas suppliers
instructions.
l If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed by a
qualified installer, service agency or gas
supplier.
INFRARED VENT-FREE
PROPANE/LP GAS
SPACE HEATER
Table of Contents
Important Safety Information.................................2
Product Features.....................................................3
Proper Ventilation & Fresh Air..............................4
Installation................................................................6
Operating Your Heater............................................10
Cleaning & Maintenance.......................................13
Trouble Shooting...................................................14
Specifications..........................................................17
Parts List..................................................................19
WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM
HEATERS
Water vapor is a by-product of gas combustion.An
unvented room heater productes approximately one (1)
ounce (30ml) of water for every 1,000 BTUs (.3KWs) of
gas input per hour. Refer to page 3.
TOLL FREE NUMBER: 1-877-886-5989
Installer: Please leave these instructions with the
consumer.
Consumer: Please retain these instructions for
future use.
ML150TPA
ML250TPA
ML150HPA
ML250HPA
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury, or loss of life.
WARNING: This is an unvented gas-
fired heater. It uses air (oxygen) from the
room in which it is installed. Provi-
sions for adequate combustion and ventila-
tion air must
be provided. Refer to Air For Com-
bustion and Ventilation section on page 4
of this manual.
PR-ML062-12-0803
CONTINENTAL APPLIANCE INC/U.S. OFFICE
5 Musick 4600 Highlands Parkway S.E.
Irvine Suite # D/E
CA 92618 Smyrna, GA 30080
Nanjing PRO-COM Electric Appliance Co.,Ltd.
#6 Chuangye Road,High New Tech.Zone,
Great Bridge Road North,Nanjing,210061,
China.
Vista de página 0
1 2 3 4 5 6 ... 24 25

Resumo do Conteúdo

Página 1 - Table of Contents

OWNER’S OPERATION AND INSTALLATION MANUAL WARNING: Improper installation,adjustment, alteration, service or mainte-nance can cause injury o

Página 2 - SAFETY INFORMATION

10Figure 15 -Equipment Shutoff ValveINSTALLATIONCHECKING GASCONNECTIONS WARNING: Test all gaspiping and connections for leaksaf

Página 3 - PRODUCT FEATURES

11Figure 17 - Control Knob in TheOFF Position Figure 18 - PilotnLIGHTINGnINSTRUCTIONS1. STOP! Read the safety information on the side

Página 4

12OPERATING YOUR HEATERTHERMOSTAT MODELSnFOR YOUR SAFETYnREAD BEFORE LIGHTING WARNING: If you do notfollow these instructions exactly

Página 5

13Figure 23 - Correct Pilot FlamePatternFigure 24 - Incorrect Pilot FlamePatternFigure 26 - Incorrect BurnerFlame PatternFigure 25 - Correct B

Página 6 - VENTILATION AIR

14TROUBLESHOOTINGNote : All troubleshootingitems are listed in order ofoperation. WARNING: Only a qualifiedservice person should

Página 7

15TROUBLESHOOTINGContinuedOBSERVED PROBLEMBurner(s)does not light afterODS/pilot is lit.Delayed ignition of burner(s).Burner backfiring duri

Página 8

16TROUBLESHOOTINGContinued WARNING: If you smell gasl Shut off gas supply.l Do not try to light any appliance.l Do not touch any electrica

Página 9

17SPECIFICATIONSNote: Dimensions listed are outer most points on the heater (includes control knobs and grill).* For purposes of input a

Página 10 - INSTALLATION

18ILLUSTRATEDPARTS BREAKDOWNML150HPABurner AssemblyODS/Pilot Assembly

Página 11 - OPERATING YOUR HEATER

19PARTS LISTML150HPAThis list contains replaceable parts for your heater. When ordering relacementparts, following the instructions lis

Página 12 - OPERATING YOUR HEATER

2IMPORTANTSAFETY INFORMATION1. This appliance is only for use with the type of gas indicated on the rating plate. This

Página 13 - CONTROL OPERATION

20ILLUSTRATED PARTSBREAKDOWNML250HPAODS/Pilot AssemblyBurner Assembly

Página 14 - TROUBLESHOOTING

21PARTS LISTML250HPAThis list contains replaceable parts for your heater. When ordering relacementparts, following the instruction list

Página 15

22ILLUSTRATEDPARTS BREAKDOWNML150TPAODS/Pilot AssemblyBurner Assembly

Página 16

23PARTS LISTML150TPAThis list contains replaceable parts for your heater. When ordering replacement parts,following the instruction lis

Página 17 - SPECIFICATIONS

24ILLUSTRATEDPARTS BREAKDOWNML250TPAODS/Pilot AssemblyBurner Assembly

Página 18 - PARTS BREAKDOWN

25PARTS LISTML250TPAThis list contains replaceable parts for your heater. When ordering replacementparts, following the instruction list

Página 19 - ML150HPA

3PRODUCT FEATURESSAFETY DEVICEA standard requirement for all vent-free roomheaters. This heater has a pilot with an OxygenDepletion Sensor(OD

Página 20 - BREAKDOWN

4FRESH AIR FORCOMBUSTION ANDVENTILATIONPROVIDING ADEQUATEVENTILATIONThe following are excerpts fromNational Fuel Gas Code. NFPA54/ANSI Z223.

Página 21 - ML250HPA

5 WARNING: Rework worksheet, add-ing the space of the adjoiningunconfined space. The combined spacesmust have enough fresh air to

Página 22

6VENTILATION AIRVentilation Air From OutdoorsProvide extra fresh air by usingventilation grills or ducts: You mustprovide two permanent

Página 23 - ML150TPA

7INSTALLATIONFigure 8 - Mounting BracketClearancesFigure 7 - Removing Lower FrontPanel of HeaterFigure 4 -Mounting Clearances AsViewed From Fr

Página 24

8INSTALLATIONFigure 11 - Mounting Heater OntoMounting BracketFigure 9 - Folding AnchorFigure 10 - Popping Open AnchorWing For Thin WallsAttach

Página 25 - ML250TPA

9INSTALLATIONCONNECTING TO GAS SUPPLY WARNING: A qualifiedservice person must connectheater to gas supply. Follow alllocal codes.

Modelos relacionados ML250HPA

Comentários a estes Manuais

Sem comentários