Procom VOR/ILS Analyzer EVS200 Manual do Utilizador Página 65

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 68
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 64
VOR/ILS Analyzer EVS200
0796.1800.02 E-8 56
Chapter 6: Technical Specification
Technical data
Receiver section
Frequency range ................................ 74.7 to 75.3 MHz
107 to 119 MHz
319 to 341 MHz
Accuracy ................................2 ppm
Resolution ................................5 kHz
Input voltage ................................15 dBm max./ 50
(data safety up to 10 dBm is ensured)
VSWR ................................<1.5
Sensitivity ................................-96 dBm 18 dB (IF bandwidth 8 kHz)
IF bandwidth ................................ min. ±15 kHz (-3 dB), max. ±40 kHz (-60dB)
min. ±4 kHz (-3 dB), max. ±12 kHz (-60dB)
or optional:
min. ±19 kHz (-6 dB), max. ±38 kHz (-60dB)
min. ±8 kHz (-6 dB), max. ±20 kHz (-60dB)
Demodulation ................................AM
RF-Input ................................ BNC
Absolute-level receiver
Display range ................................-96 to +10 dBm
Accuracy ................................< ±2dB
Difference-level receiver
Bargraph (quasi analog)...................... ±12 dB to reference level
Resolution ................................ 0.1 dB
Accuracy indication .............................≤±1dB
ILS signal analysis
Thegivenvaluesarevalidonlyforthe30kHz-or38kHz-IF-filter
RF level ................................-70 to -30 dBm
Frequency range ................................ 108 to 118 MHz
................................328 to 336 MHz
Modulation depth (10 to 80 %)
90 / 150 Hz ±2% ................................accuracy 0.5%
300 Hz to 4 kHz (identifier)..................1.2% of reading
Phase angle 90/150 Hz
Measurement range............................±60°
Measurement error..............................0.2°
Resolution ................................ 0.1°
DDM measurement
Localizer mode
Measurement error at
15 to 25% modulation.......................... ≤±0.0004 DDM
±0.1% of reading
10 to 30% modulation.......................... ≤±0.0004 DDM
±0.2% of reading
Vista de página 64