CONFIGURATION:___________________________
There are three aspects of the ProComm that require configuration.
• Radio Channel
• Relays Normally Open or Normally Closed
• Programming
Radio Channel Configuration
The ProComm supports eight channels to avoid interaction when multiple
ProComm systems are employed in close proximity situations. The radio
channel can be configured at the factory prior to shipment or by a technician
in the field. See the configuration sheet to specify a channel for factory
configuration.
Channel Frequency
0 903.37 MHz
1* 906.37 MHz*
2 907.87 MHz
3 909.37 MHz
4 912.37 MHz
5 915.37 MHz
6 919.87 MHz
7 921.37 MHz
*Factory default channel selection
For safety reasons, on site radio channel configuration requires
the following basic steps.
1. Power down and lock out any systems that could be
operating at the frequencies shown above.
2. Set the TriggerPad channel. (See instructions below.)
3. Set the channel of the ProComm. (Refer to the appropriate
receiver user manual, i.e. ProComm 100, for receiver
configuration.)
4. Return processes and equipment to service.
Please note, to avoid accidentally duplicating channels, it is
recommended that the default channel NOT be used in a multi-
station application.