PWR
This indicator is located above the J1 (TERM) connector. When illuminated
with a steady red light, the PWR LED indicates that power is being applied
to the unit and the internal circuitry is operating properly. If
communication between internal components is lost the ProComm will
disable all outputs and the PWR LED will blink.
RUN
This indicator is located above the J1 (TERM) connector. When illuminated
with a steady red light, the RUN LED indicates normal program operation.
When communication is present from a transmitter using the proper
channel, the RUN LED will blink.
A
This indicator is located above the J2 (INPUT) connector. When illuminated
with a steady red light, the A LED indicates an input of 120VAC nominal
applied between J2-1 and J2-2.
B
This indicator is located above the J2 (INPUT) connector. When illuminated
with a steady red light, the B LED indicates an input of 120VAC nominal
applied between J2-3 and J2-4.
1-8
This set of indicators is located above the J3 (OUTPUT) connector. When
illuminated with a steady red light, each LED indicates an active coil on the
corresponding relay. Actual relay output state depends on n/o or n/c
configuration.